PT provider
PT provider KYMI LTDA KYMI LTDA
Based in Brazil
Language(s) Englisch
Remarks Calculations based on ISO standards. For PT scores, the Scheme follows ISO 13528. Target values for interlaboratory standard deviation is not based in the round of test, but in constant international references, making it possible to evaluate performance on a long term basis in time. The assigned value for the materials is normally taken from the certificate (when CRM are used, which is often). When CRM are not used, the results obtained in the round are used for later certification of the material. Two samples are sent each three months, results are required in triplicate from each participant. For the final evaluation in certification of reference materials, ISO 5725-2 and ISO 5725-5 are used. Also for collaborative work, method validation, calculations are done in accordance with ISO 5725-2 and ISO 5725-5.
Keywords
Product groups Minerals
Testing fields Analytical chemistry
Technical details
Test item Tested property Testing method
Iron Ores AL2O3 X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
CaO X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Atomic absorption spectrometry (AAS)
Fe X-ray fluorescence spectrometry (XRF)
Volumetric analysis / titrimetry
FeO Volumetric analysis / titrimetry
K2O X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Atomic absorption spectrometry (AAS)
LOI (loss on ignition) Gravimetric method
MgO X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Atomic absorption spectrometry (AAS)
Mn X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Atomic absorption spectrometry (AAS)
Na2O X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Atomic absorption spectrometry (AAS)
P X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Spectrophotometry, UV/VIS
SiO2 X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Gravimetric Analysis
TiO2 X-ray fluorescence spectrometry (XRF)
ICP-AES / ICP-OES
Aims of the PT scheme
Target group of participants Iron Ore Laboratories in Mining Operations, Steel Works, Mineral and Metallurgical Research Centres, Inspection Organisations, Universities. There are no geographical restrictions.
Linked to specific legislation / standards No
Additional, subsidiary aims characterisation of reference materials and validation of testing methods
Number of participants 14
Accredited or otherwise reviewed by a 3rd party
Operation is commissioned / requested by No
Fees and frequency
Participation fee US $ 3.100,00
Regularly operated Yes (three months)
Year of first operation 2016
Contact details of the PT provider
Provider Contact person
KYMI LTDA
CX Postal 202
34007-970
Brazil

Phone: +55 31 31282525
Fax:
Web: http://kymi.com.br http://kymi.com.br
Mr Marcio Castilho
Phone: 31996155082
Fax:
Email: marcio@kymi.com.br marcio@kymi.com.br
If you find any mistakes please contact the responsible EPTIS coordinator in Brazil, Mr José Ricardo Bardellini da Silva. Mr José Ricardo Bardellini da Silva.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5