EPTIS
BAM Logo

HLA Diagnostics 06 – HLA Antibody Screening and Identification (445)

[HLA-Diagnostik 06 - HLA-Antikörper-Nachweis und -Spezifizierung (445)]

EPTIS factsheet 160453 | Last revision 2023-10-23 | URL: https://www.eptis.bam.de/pts160453 https://www.eptis.bam.de/pts160453

PT provider
PT provider INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories
Based in Germany
Language(s) German, English
Remarks The interdisciplinary, non-profit, scientific and medical association INSTAND e. V. is a reference institution for the quality control of medical laboratories. It is one of three reference institutions appointed by the German Medical Association and, thus, responsible for the organization of external quality assessment (EQA) schemes for quality control in medical laboratories. You can register for EQAs, submit your results as PDF via https://rv-online.instandev.de. This price applies exclusively to orders placed via INSTAND e.V. Prices and services may differ for orders placed via distributors.
Keywords
Product groups Human test material
Testing fields Medical analysis
Technical details
Test item Tested property Testing method
5 Samples of Human serum, 1 ml each HLA antibody detection by CDC without DTT -
HLA antibody detection by CDC with DTT -
HLA antibody detection by SPA class I -
HLA antibody detection by SPA class II -
HLA-antibody specification by CDC: HLA-A -
HLA-antibody specification by CDC: HLA-B -
HLA-antibody specification by CDC: HLA-Cw -
HLA-antibody specification by SPA class I: HLA-A -
HLA-antibody specification by SPA class I: HLA-B -
HLA-antibody specification by SPA class I: HLA-Cw -
HLA-antibody specification by SPA class II: HLA-DRB -
HLA-antibody specification by SPA class II: HLA-DRB3/4/5 -
HLA-antibody specification by SPA class II: HLA-DQA -
HLA-antibody specification by SPA class II: HLA-DPB -
HLA-antibody specification by SPA class II: HLA-DPA -
HLA-antibody specification by complement-binding assay class I: HLA-A -
HLA-antibody specification by complement-binding assay class I: HLA-B -
HLA-antibody specification by complement-binding assay class I: HLA-Cw -
HLA-antibody specification by complement-binding assay class II: HLA-DRB -
HLA-antibody specification by complement-binding assay class II: HLA-DRB3/4/5 -
HLA-antibody specification by complement-binding assay class II: HLA-DQB -
HLA-antibody specification by complement-binding assay class II: HLA-DQA -
HLA-antibody specification by complement-binding assay class II: HLA-DPB -
HLA-antibody specification by complement-binding assay class II: HLA-DPA -
Aims of the PT scheme
Target group of participants
Linked to specific legislation / standards
Additional, subsidiary aims
Number of participants <50
Accredited or otherwise reviewed by a 3rd party

Accredited by DAkkS (Germany) on the basis of ISO/IEC 17043

German Bundesärztekammer (General medical Council)

Operation is commissioned / requested by
Fees and frequency
Participation fee 272 Euro
Regularly operated Yes (2 times per year)
Year of first operation Experience with operation of ILCs since 1968
Contact details of the PT provider
Provider Contact person
INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories
P.O.Box 250211, Ubierstrasse 20
40223 Düsseldorf
Germany

Phone: +49-211-159213-0
Fax:
Web: http://www.instandev.de/ http://www.instandev.de/
Dr. rer. nat. Nathalie Weiss
Phone: +49-211-159213430
Fax:
Email: weiss@instand-ev.de weiss@instand-ev.de
If you find any mistakes please contact the responsible EPTIS coordinator in Germany, Mr Johannes van de Kreeke. Mr Johannes van de Kreeke.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5