Sequencial Schem AC/ DC Current . Voltage , Resistance , Capacitance , Frequency , Temperature Simulation - RTD
[Sequencial Schem AC/ DC Current . Voltage , Resistance , Capacitance , Frequency , Temperature Simulation - RTD ]
EPTIS Ringversuch Nr. 1588119 | Letze Änderung 2026-08-05 | URL: https://www.eptis.bam.de/pts1588119 https://www.eptis.bam.de/pts1588119
| Name des Anbieters | |||||||||||||
| Name des Anbieters | Research Consultant Research Consultant | ||||||||||||
| Ansässig in | Saudi Arabia | ||||||||||||
| Sprache(n) | English | ||||||||||||
| Anmerkungen | The scheme is technically valid provided the reference laboratory's CMC is at least three times better than the participant's claimed uncertainty; otherwise the discriminating power of En is weak. Traceability of the artefact (standard resistor, DC voltage source, multifunction calibrator, or transfer standard) must be unbroken to SI, with documented drift history and stability during circulation. Environmental influence quantities — temperature, humidity, thermal EMF, self-heating, lead resistance, loading effect, and connection technique — must be recorded, as these dominate the error budget in DC/LF electrical measurement. Uncertainty budgets submitted by participants should be reviewed for completeness; an unsatisfactory En often arises from understated uncertainty rather than measurement bias. The single-laboratory approach is acceptable under ISO/IEC 17043 and satisfies ILAC-P9 requirements for participation, but it does not provide the peer-group comparison of a full round-robin, so conclusions are limited to bilateral agreement with the reference laboratory.The scheme is fit for purpose for demonstrating measurement competence and traceability in electrical parameters, subject to satisfactory En values and a robust reference laboratory uncertainty claim. Registration Link - https://docs.google.com/forms/d/e/1FAIpQLSezN1gG7uUZP6A5YWvYrMz55I2z64zC3gRn0BpEgu5CV-MD3A/viewform?usp=sharing&ouid=114566084934239227737 | ||||||||||||
| Klassifizierung | |||||||||||||
| Produktgruppen |
Electrical / electronical devices
|
||||||||||||
| Prüfgebiete |
Calibration
|
||||||||||||
| Technische Einzelheiten | |||||||||||||
|
|||||||||||||
| Ringversuchsziele | |||||||||||||
| Zielgruppe des Ringversuchs | Calibration Laboratory | ||||||||||||
| Relevante Rechtsvorschriften oder Normen | Euramet Cg-15 | ||||||||||||
| Weitere Ziele | validation of testing methods | ||||||||||||
| Teilnehmerzahl | 8 to 10 | ||||||||||||
| Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt) |
Akkreditiert durch IQAS auf der Grundlage von ISO/IEC 17043 :2023 |
||||||||||||
| Die Durchführung des Ringversuchs ist in Auftrag gegeben durch | yes | ||||||||||||
| Kosten | |||||||||||||
| Teilnahmegebühr | 150 USD without transportation charges | ||||||||||||
| Regelmässig durchgeführt | Ja (1) | ||||||||||||
| Der Ringversuch wird durchgeführt seit | 2026 | ||||||||||||
| Kontaktdaten des Anbieters | |||||||||||||
| Anbieter | Kontaktperson | ||||||||||||
|
Research Consultant
Saudi Arabia Telefon: +91 9840624529 Fax: |
Technical Manager Abdullah S
Telefon: +919840624529 Fax: E-Mail: abdullah@research-consultant.net abdullah@research-consultant.net |
||||||||||||