EPTIS
BAM Logo

Electromagnetic Compatibility (EMC)

EPTIS factsheet 1570201 | Last revision 2026-04-17 | URL: https://www.eptis.bam.de/pts1570201 https://www.eptis.bam.de/pts1570201

PT provider
PT provider Normus Proficiency Testing Services LLC Normus Proficiency Testing Services LLC
Based in United States
Language(s) English
Remarks 0801: EN 61000-4-4 Electrical fast transient / burst immunity (Burst) 0802: EN 61000-4-5 Surge immunity 0803: EN 55011 Radio-frequency disturbance characteristics (Conducted emission) 0804: EN 61000-4-11 Voltage dips, short interruptions and voltage variations immunity 0805: EN 61000-4-2 Electrostatic discharge immunity (ESD) 0806: EN 55014-1 Emission - Disturbance power 0807: EN 55014-1 Emission - Discontinuous disturbance - click (Click) 0808: EN 55011 Radiated emission 0809: EN 61000-4-8 Power frequency magnetic field immunity test 0810: MIL STD 461F CE101: Conducted Emissions, Power Leads (30 Hz - 10 kHz) 0811: MIL STD 461F CE102: Conducted Emissions, Power Leads (10 kHz - 10 MHz) 0812: MIL STD 461F CS101: Conducted Susceptibility, Power Leads (30 Hz - 150 kHz) 0813: MIL STD 461F CS109: Conducted Susceptibility, Structure Current (60 Hz - 100 kHz) 0814: MIL STD 461F CS114: Conducted Susceptibility, Bulk Cable Injection (10 kHz - 200 MHz) 0815: MIL STD 461F CS115: Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation 0816: MIL STD 461F CS116: Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads (10 kHz - 100 MHz) 0817: MIL STD 461F RE101: Radiated Emissions, Magnetic Field (30 Hz - 100 kHz) 0818: MIL STD 461F RE102: Radiated Emissions, Electric Field (10 kHz - 18 GHz) 0819: MIL STD 461F RS101: Radiated Susceptibility, Magnetic Field (30 Hz - 100 kHz)
Keywords
Product groups Electrical / electronical devices
Testing fields Electrotechnics / electronics
Technical details
Test item Tested property Testing method
Civil and military electrical, electronic, electromechanical devices, subsystems, identical and representative components Emission Measurement of conducted and radiated electromagnetic emissions using EMI receivers and antennas.
Immunity Performance verification under conducted and radiated electromagnetic disturbances.
MIL-STD-461F EMC testing procedures for military equipment according to CE, RE, CS, and RS methods defined in MIL-STD-461F.
Aims of the PT scheme
Target group of participants Laboratories that perform electrical tests. No geographical restrictions.
Linked to specific legislation / standards Directive 2014/30/EU MIL-STD-461F EN 61000 series
Additional, subsidiary aims validation of testing methods
Number of participants min.8
Accredited or otherwise reviewed by a 3rd party
Operation is commissioned / requested by
Fees and frequency
Participation fee Each test item has a different price. The average price is $750 per test item. Please contact us for more information.
Regularly operated Yes (Once a year)
Year of first operation 2019
Contact details of the PT provider
Provider Contact person
Normus Proficiency Testing Services LLC
169 Madison Ave STE 11534 Unit 316
10016 New York, NY
United States

Phone: +1 (332) 254 6040
Fax:
Web: https://www.normuspt.com https://www.normuspt.com
Mr. Oguzhan YALNIZ
Phone: +1 (332) 254 6040
Fax:
Email: info@normuspt.com info@normuspt.com
If you find any mistakes please contact the responsible EPTIS coordinator in United States, Mr Johannes van de Kreeke. Mr Johannes van de Kreeke.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5