PT provider
PT provider CERTIFYC.A. CERTIFYC.A.
Based in Italy
Language(s) Italian - English
Remarks Information for the participants: Gaseous emissions reproduced in the LOOP are comparable to real exhaust gases generated by combustion. The flow rate, velocity, and total dust tests are performed on the vertical STACK section. For both the LOOP and STACK, 12 stations are available, fully compliant with UNI ISO 15259. The tests may engage the laboratories for 2 or 3 days. More details can be found at the following link: https://www.certify-ca.it
Keywords
Product groups Emissions
Testing fields Emissions of gases / vapours
Technical details
Test item Tested property Testing method
Gas Emissions - LOOP Oxygen (O2) UNI EN 14789:2017
Carbon dioxide (CO2) ISO 12039:2019 (method IR)
UNI CEN/TS 17405:2020
UNI CEN/TS 17337:2019
Carbon monoxide (CO) UNI EN 15058:2017
UNI CEN/TS 17337:2019
Nitrogen Oxides (NOx) UNI EN 14792:2017
Nitrous Oxide (N2O) UNI EN ISO 21258:2010
UNI CEN/TS 17337:2019
Sulfur Dioxide (SO2 - Automated test processor) UNI CEN/TS 17021:2017
UNI CEN/TS 17337:2019
Sulfur Dioxide (SO2 - Reference method) UNI EN 14791:2017
Humidity - Water Content (H2O) UNI EN 14790:2017
UNI CEN/TS 17337:2019
TOC (total organic carbon) - FID method UNI EN 12619:2013
Ammonia (NH3) UNI EN ISO 21877:2020
UNI CEN/TS 17337:2019
Hydrochloric acid (HCl) UNI EN 1911:2010
UNI CEN/TS 17337:2019
Hydrofluoric acid (HF) ISO 15713:2006
UNI CEN/TS 17337:2019
Formaldehyde (C2H2) CEN/TS 17638:2021
UNI CEN/TS 17337:2019
Gas Emissions - STACK Flow rate and velocity UNI EN ISO 16911-1:2013 Annex-A
Total dust UNI EN 13284-1:2017
Aims of the PT scheme
Target group of participants Open to all companies
Linked to specific legislation / standards NO
Additional, subsidiary aims characterisation of reference materials
Number of participants minimum 5, up to 24
Accredited or otherwise reviewed by a 3rd party
Operation is commissioned / requested by NO
Fees and frequency
Participation fee 450-3.500 euro depending on the tested properties
Regularly operated Yes (monthly or every two months)
Year of first operation 5-6 time per year
Contact details of the PT provider
Provider Contact person
CERTIFYC.A.
Via Santa Barbara n° 16
Albano Sant'Alessandro (BG)
Italy

Phone: 00393336468572
Fax: +39 035 65 94 497
Web: http://www.certify-ca.it http://www.certify-ca.it
Dott. Giorgio Grilli
Phone: 00393336468572
Fax:
Email: giorgio.grilli@certify-ca.it giorgio.grilli@certify-ca.it
If you find any mistakes please contact the responsible EPTIS coordinator in Italy, Ms Laura Galli. Ms Laura Galli.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5