Calibration of a reference oscillator + frequency counter + two signal generators

[Taratura di un oscillatore di riferimento + un frequenzimetro + due generatori di segnali sintetizzati]

EPTIS Ringversuch Nr. 1439769 | Letze Änderung 2025-11-03 | URL: https://www.eptis.bam.de/pts1439769 https://www.eptis.bam.de/pts1439769

Name des Anbieters
Name des Anbieters La Giusta Misura s.a.s. La Giusta Misura s.a.s.
Ansässig in Italy
Sprache(n) English, Italian
Anmerkungen - Calibration of the reference oscillator is performed with the oscillator phase locked to the internal GPS receiver. - Calibration of the frequency counter and the signal oscillators are performed with the time base phase locked to the reference oscillator - Partial calibration, related to measuring functions or measuring ranges, is allowed. - An antenna for receiving the GPS signal and an antenna signal splitter (for laboratories using their own GPS antenna) are provided. - The calibration uncertainties (CMC) of the reference laboratory are as follows: reference oscillator: U = 5E-13 signal generators: U = 2,4E-12 (f > 0,2 Hz); 6,2E-12 (f = 0,1 Hz) frequency counter: U = from 2E-12 to 1,3E-11 (f > 0,5 Hz); 1E-6 (f = 0,1 Hz)
Klassifizierung
Produktgruppen Electrical / electronical devices
Prüfgebiete Calibration
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
Frequency counter Fluke PM6690 Frequency counter errors on decadic frequency values from 0,1 Hz to 2,7 GHz with time base from the reference oscillator Frequency counter calibration by comparison with frequency reference signals
Signal generator HP3325B Signal generator errors on decadic frequency values from 0,1 Hz to 10 MHz, phase locked to the reference oscillator Calibration of the signal generator by means of reference frequency measurements
Reference oscillator HP58503A Frequency of reference output signal (10MHz) phase locked to an internal GPS receiver High accuracy frequency measurement
Signal generator Agilent 83630 Signal generator errors on decadic frequency values from 10 MHz to 20 GHz, phase locked to the reference oscillator Calibration of the signal generator by means of reference frequency measurements
Ringversuchsziele
Zielgruppe des Ringversuchs European Calibration Laboratories
Relevante Rechtsvorschriften oder Normen no
Weitere Ziele validation of testing methods
Teilnehmerzahl 10
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)

Akkreditiert durch no auf der Grundlage von

no

Die Durchführung des Ringversuchs ist in Auftrag gegeben durch no
Kosten
Teilnahmegebühr 1400 euro
Regelmässig durchgeführt Ja (once every two years)
Der Ringversuch wird durchgeführt seit 2026 January
Kontaktdaten des Anbieters
Anbieter Kontaktperson
La Giusta Misura s.a.s.
via G. Verdi 11
24068
Italy

Telefon: +39 3284931186
Fax:
Web: https://www.lagiustamisura.it https://www.lagiustamisura.it
ing. Aldo Ponterio
Telefon: +39 3284931186
Fax:
E-Mail: info@lagiustamisura.it info@lagiustamisura.it
Haben Sie einen Fehler entdeckt? Bitte wenden Sie sich an den zuständigen EPTIS Koordinator für Italy, Ms Laura Galli. Ms Laura Galli.
Haben Sie Fragen? Senden Sie uns eine E-Mail: eptis@bam.de.
Anwendungsversion: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5