Language(s)
Remarks Three liquid human serum samples covering an appropriate range for the diagnosis and monitoring of Cholestasis in Pregnancy. A linear series of up to 9 pools are prepared in serum containing a mixture of Cholic acid and Deoxycholic acid, the ratio of which reflects both physiological levels and pathological levels observed in ICP. Target values for both Cholic acid and Chenodeoxycholic acid are assayed using a ID – GC Mass Spectrometer for each sample. The programme is designed to assess laboratory and method performance, including bias, within and between batch imprecision, linearity, trueness, sensitivity and specificity of TSBA. Key Features: Linear panels assigned by a higher meteorological order reference method. Panel of liquid human serum samples covering an appropriate range and BA ratio for the diagnosis and monitoring of ICP Challenging samples containing UDCA and other BA to determine specificity. Analytical performance Specification based on Milan Model 3. For more information: https://www.weqas.com/services/eqa/bileacid/ or contact@weqas.com
Keywords
Product groups Health care / medical devices
Testing fields Medical analysis
Technical details
Test item Tested property Testing method
Off the clot human serum Total Bile Acids Routine testing methods (recommended)
Cholic Acid Routine testing methods (recommended)
Dexycholic Acid Routine testing methods (recommended)
Aims of the PT scheme
Target group of participants Laboratory Diagnostic Services
Linked to specific legislation / standards Accreditation by UKAS on the basis of ISO/IEC 17043.
Additional, subsidiary aims validation of testing methods
Number of participants
Accredited or otherwise reviewed by a 3rd party

Accredited by UKAS on the basis of ISO/ IEC 17043

Operation is commissioned / requested by
Fees and frequency
Participation fee Fee dependent on number of participating sections and proximetry of testing methods.
Regularly operated Yes (Frequency: Monthly. Samples: 3 x 0.5 mL)
Year of first operation 2004
Contact details of the PT provider
Provider Contact person
Weqas
Unit 6, Parc Ty Glas
CF14 5DU Cardiff
United Kingdom

Phone: 44 (0) 2920 314750
Fax:
Web: http://www.weqas.com http://www.weqas.com
Laura Lloyd-Lewis
Phone: 44 (0) 29218 32884
Fax:
Email: laura.lloyd-lewis@wales.nhs.uk laura.lloyd-lewis@wales.nhs.uk
If you find any mistakes please contact the responsible EPTIS coordinator in United Kingdom, Mr Savvas Xystouris. Mr Savvas Xystouris.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5