[Haematinics ]

EPTIS Ringversuch Nr. 142620 | Letze Änderung 2024-05-22 | URL: https://www.eptis.bam.de/pts142620 https://www.eptis.bam.de/pts142620

Name des Anbieters
Name des Anbieters Weqas Weqas
Ansässig in United Kingdom
Sprache(n)
Anmerkungen The Haematinic panel of tests are often undertaken on routine Immunoassay and spectrophotometric platforms used by Medical Biochemistry Departments and are no longer confined to specialist Haematology Departments. Ferritin is used as an indicator of iron status. A ferritin of <30ug/L is indicative of iron deficiency, whilst an elevated level (>400 ug/L) is indicative of iron overloading such as haemosiderosis or haemochromatosis. Elevated ferritin values are also encountered in certain tumours: acute leukaemia, Hodgkins disease and carcinoma of the lung, colon, liver and prostate. Investigation of folate deficiency may be indicated when nutritional, macrocytic or megaloblastic anaemias are suspected. Since a deficiency of either vitamin B12 or folate can cause megaloblastic anaemia, both tests are indicated in order to diagnose the aetiology of anaemia. Four liquid human serum samples are distributed monthly, with a minimum of 48 samples distributed over the year covering a wide clinically relevant range. The material is prepared from endogenous samples donated by polycythaemic, hemochromatosis, renal patients and healthy volunteers. The samples consist of a panel of 10 samples distributed on a number of occasions over that period which are used to assess both laboratory and method performance, including linearity, bias, within and between batch imprecision. Additional challenging samples spiked with iron traceable to NIST SRM #928 are distributed to assess the performance at mild and severely toxic levels. Key Features: - Commutable, endogenous samples from patients and volunteers. - Challenging samples assess the performance at mild and severely toxic levels of iron. - Liquid human serum samples require no pre-analytical preparation. - Sample cover a wide clinically relevant range. - Scoring based on Milan Model 3 performance specification. For more information: https://www.weqas.com/services/eqa/haematinics/ or contact@weqas.com
Klassifizierung
Produktgruppen Health care / medical devices
Prüfgebiete Medical analysis
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
Off the clot human serum Ferritin Routine testing methods (recommended)
B12 Routine testing methods (recommended)
Active B12 Routine testing methods (recommended)
Folate Routine testing methods (recommended)
Iron Routine testing methods (recommended)
TIBC Routine testing methods (recommended)
Transferrin Routine testing methods (recommended)
Transferrin Saturation Routine testing methods (recommended)
Ringversuchsziele
Zielgruppe des Ringversuchs This Programme covers the main parameters assayed by Biochemistry Departments.
Relevante Rechtsvorschriften oder Normen Accreditation by UKAS on the basis of ISO/IEC 17043
Weitere Ziele validation of testing methods
Teilnehmerzahl
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)

Akkreditiert durch UKAS auf der Grundlage von ISO/IEC 17043

Die Durchführung des Ringversuchs ist in Auftrag gegeben durch
Kosten
Teilnahmegebühr https://www.weqas.com/participantzone/subscription-charges/
Regelmässig durchgeführt Ja (Frequency: Monthly. Samples: 4 x 1.0mL.)
Der Ringversuch wird durchgeführt seit 1996
Kontaktdaten des Anbieters
Anbieter Kontaktperson
Weqas
Unit 6, Parc Ty Glas
CF14 5DU Cardiff
United Kingdom

Telefon: 44 (0) 2920 314750
Fax:
Web: http://www.weqas.com http://www.weqas.com
Laura Lloyd-Lewis
Telefon: 44 (0) 29218 32884
Fax:
E-Mail: laura.lloyd-lewis@wales.nhs.uk laura.lloyd-lewis@wales.nhs.uk
Haben Sie einen Fehler entdeckt? Bitte wenden Sie sich an den zuständigen EPTIS Koordinator für United Kingdom, Mr Savvas Xystouris. Mr Savvas Xystouris.
Haben Sie Fragen? Senden Sie uns eine E-Mail: eptis@bam.de.
Anwendungsversion: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5