High-sensitivity Troponin

[High-sensitivity Troponin]

EPTIS Ringversuch Nr. 142542 | Letze Änderung 2024-05-21 | URL: https://www.eptis.bam.de/pts142542 https://www.eptis.bam.de/pts142542

Name des Anbieters
Name des Anbieters Weqas Weqas
Ansässig in United Kingdom
Sprache(n)
Anmerkungen High sensitivity cardiac Troponin (hs-cTn) T and I have replaced standard Troponin assays, myoglobin and Creatine kinase – MB as the preferred markers of myocardial injury. NICE diagnostic guidance – [DG40], High sensitivity troponin tests for the early rule out of NSTEMI, published in August 2020 recommended a number of hs-cTn methods that could be used for the early rule out of non-ST-segment elevation myocardial infarction (NSTEMI) in people presenting to an emergency department with chest pain and suspected acute coronary syndrome. The hsTropnin EQA programme is available as serum samples. Three liquid human serum samples are distributed monthly, with a minimum of 36 samples distributed over the year covering a wide clinical range. The samples consist of endogenous samples from patients along with a panel of linearly related samples produced from donations from healthy volunteers spiked with Cardiac Troponin. The programme includes samples at clinically relevant ranges at or near the limit of detection, samples at the 99th centiles, thresholds for early rule out and at high hs-cTn concentrations seen in myocardial infarction. The samples are distributed on a number of occasions over the year which allows for the assessment of the laboratory’s and method’s performance, including linearity, bias, within and between batch imprecision. Key Features: - Includes challenging samples at limits of detection and diagnostic “99th centile” for hs-cTnT and hs-cTnl. - Liquid human serum samples require no pre-analytical preparation. - Linearly related panel covering a clinically relevant range. For more information: https://www.weqas.com/services/eqa/hs-troponin/ or contact@weqas.com
Klassifizierung
Produktgruppen Health care / medical devices
Prüfgebiete Medical analysis
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
Off the clot human serum hsTroponin I (hs-cTnl) Routine testing methods (recommended)
hsTroponin T (hs-cTnT) Routine testing methods (recommended)
Ringversuchsziele
Zielgruppe des Ringversuchs The Programme aims to assess the performance of organisations utilising biochemical cardiac markers to aid in the diagnosis of acute coronary syndrome (ACS) and cardiac ischaemia.
Relevante Rechtsvorschriften oder Normen Accreditation by UKAS on the basis of ISO/IEC 17043
Weitere Ziele validation of testing methods
Teilnehmerzahl
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)

Akkreditiert durch UKAS auf der Grundlage von ISO/IEC 17043

Die Durchführung des Ringversuchs ist in Auftrag gegeben durch
Kosten
Teilnahmegebühr https://www.weqas.com/participantzone/subscription-charges/
Regelmässig durchgeführt Ja (Frequency: Monthly. Samples: 3 x 1.0mL.)
Der Ringversuch wird durchgeführt seit 2005
Kontaktdaten des Anbieters
Anbieter Kontaktperson
Weqas
Unit 6, Parc Ty Glas
CF14 5DU Cardiff
United Kingdom

Telefon: 44 (0) 2920 314750
Fax:
Web: http://www.weqas.com http://www.weqas.com
Laura Lloyd-Lewis
Telefon: 44 (0) 29218 32884
Fax:
E-Mail: laura.lloyd-lewis@wales.nhs.uk laura.lloyd-lewis@wales.nhs.uk
Haben Sie einen Fehler entdeckt? Bitte wenden Sie sich an den zuständigen EPTIS Koordinator für United Kingdom, Mr Savvas Xystouris. Mr Savvas Xystouris.
Haben Sie Fragen? Senden Sie uns eine E-Mail: eptis@bam.de.
Anwendungsversion: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5