[Blood Gas]

EPTIS Ringversuch Nr. 142494 | Letze Änderung 2024-05-22 | URL: https://www.eptis.bam.de/pts142494 https://www.eptis.bam.de/pts142494

Name des Anbieters
Name des Anbieters Weqas Weqas
Ansässig in United Kingdom
Sprache(n)
Anmerkungen The Programme aims to assess the performance of organisations utilising blood gas analysers to aid in the diagnosis of the patient’s acid base balance and the status of routinely measured electrolytes and metabolites. The standard aqueous material includes the addition of protein which minimises the risk of preanalytical sampling error due to the protein foam layer. The protein material also highlights errors in electrolyte analysis that cannot be detected by other aqueous controls. The tonometered protein based aqueous material is distributed monthly, covering blood gases, electrolytes and metabolites including Haematocrit, Urea, Creatinine and Lactate. A wide clinical range is covered including challenging samples at low pO2 and low iCa++ concentration. The latter is suitable for the evaluation of instruments used in the monitoring of patients on citrate anticoagulation for Continuous Renal Replacement Therapy (CRRT). Three aqueous samples are distributed monthly, with a minimum of 33 samples distributed over the year covering a wide clinically relevant range. The samples consist of a panel of 6 linearly related samples distributed on a number of occasions over that period. Key Features: - Weqas’ aqueous material minimises the risk of pre-analytical error sampling due to its protein foam layer. - Additional stable whole blood material distributed once a year for accuracy assessment of pO₂ and additional secondary parameters; base excess and Oxygen Saturation. - Wide clinical range covered over the course of the year including challenging samples. - Programme assesses both laboratory and method performance, including bias, within and between batch imprecision. - Both materials are suitable for use for the majority of PoCT and Laboratory analysers. For more information: https://www.weqas.com/services/eqa/bloodgas/ or contact@weqas.com
Klassifizierung
Produktgruppen Health care / medical devices
Prüfgebiete Medical analysis
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
Tonometered protein buffered aqueous solution and whole blood pH Routine testing methods (recommended)
H+ Routine testing methods (recommended)
pCO2 Routine testing methods (recommended)
pO2 Routine testing methods (recommended)
Actual Bicarbonate Routine testing methods (recommended)
TCO2 Routine testing methods (recommended)
Na+ Routine testing methods (recommended)
K+ Routine testing methods (recommended)
CI Routine testing methods (recommended)
Magnesium Routine testing methods (recommended)
iCa++ Routine testing methods (recommended)
Glucose Routine testing methods (recommended)
Lactate Routine testing methods (recommended)
Urea Routine testing methods (recommended)
Creatinine Routine testing methods (recommended)
Haematocrit (iStat only) Routine testing methods (recommended)
Lithium Routine testing methods (recommended)
SBCe Routine testing methods (recommended)
BE Routine testing methods (recommended)
sO2 Routine testing methods (recommended)
Ringversuchsziele
Zielgruppe des Ringversuchs The Programme is available to both Laboratory and Point of Care testing sites.
Relevante Rechtsvorschriften oder Normen Accreditation by UKAS on the basis of ISO/IEC 17043
Weitere Ziele validation of testing methods
Teilnehmerzahl
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)

Akkreditiert durch UKAS auf der Grundlage von ISO/IEC 17043

Die Durchführung des Ringversuchs ist in Auftrag gegeben durch
Kosten
Teilnahmegebühr https://www.weqas.com/participantzone/subscription-charges/
Regelmässig durchgeführt Ja (Frequency: Monthly. Samples: 3 x 2.5mL.)
Der Ringversuch wird durchgeführt seit 1994
Kontaktdaten des Anbieters
Anbieter Kontaktperson
Weqas
Unit 6, Parc Ty Glas
CF14 5DU Cardiff
United Kingdom

Telefon: 44 (0) 2920 314750
Fax:
Web: http://www.weqas.com http://www.weqas.com
Laura Lloyd-Lewis
Telefon: 44 (0) 29218 32884
Fax:
E-Mail: laura.lloyd-lewis@wales.nhs.uk laura.lloyd-lewis@wales.nhs.uk
Haben Sie einen Fehler entdeckt? Bitte wenden Sie sich an den zuständigen EPTIS Koordinator für United Kingdom, Mr Savvas Xystouris. Mr Savvas Xystouris.
Haben Sie Fragen? Senden Sie uns eine E-Mail: eptis@bam.de.
Anwendungsversion: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5