EPTIS Ringversuch Nr. 1278602 | Letze Änderung 2026-03-19 | URL: https://www.eptis.bam.de/pts1278602 https://www.eptis.bam.de/pts1278602

Name des Anbieters
Name des Anbieters QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd. QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Ansässig in Hungary
Sprache(n) English, Hungarian
Anmerkungen Clinical applicability: diagnostics and monitoring of Vasculitis. Qualitative results are evaluated in the scheme. QualiCont has had accredited status as the QualiCont as a Proficiency Test Provider complies with the criteria of MSZ EN ISO/IEC 17043:2010 standard since 26 March 2014. The QualiCont has been accredited according to the MSZ EN ISO/IEC 17043:2023 standard since 18 December 2025. Our Company is a Proficiency Testing Provider Organisation accredited by NAH (National Accreditation Authority) under the NAH-8-0002/2023 registration number. As the result of the accreditation process performed by NAH, our Company has accredited status until 9 March 2028. QualiCont Nonprofit Kft. has been operating its quality management system since 2001. Our Company successfully passed the renewal audit on 6th May, 2025. The certificate is valid until 28 May 2028. Our Company has been assessed and certified as meeting the requirements of ISO 9001:2015 standard for the following activities: Planning, organization and management of proficiency testing (external quality assessment) and the related supporting services for in vitro medical diagnostic laboratories and investigators on other human and veterinary medicine.
Klassifizierung
Produktgruppen Health care / medical devices
Human test material
Prüfgebiete Medical analysis
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
2 samples of 0.5 mL lyophilised serum/plasma each ANCA screen Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
Anti MPO Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
Anti PR3 Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
Atypical ANCA (IIFT) Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
cANCA (IIFT) Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
pANCA (IIFT) Enzyme immunoassay (ELISA)
Immunoblot/Western blot/dot blot
Indirect Immunofluorescence test (IIFT)
Radioimmunoassay (RIA)
Ringversuchsziele
Zielgruppe des Ringversuchs In vitro medical laboratories
Relevante Rechtsvorschriften oder Normen CLSI GP44-A4 – Procedures for Handling and Processing of Blood Specimens for Common Laboratory Tests ILAC_G8:09/2019 – Guidelines on Decision Rules and Statements of Conformity ISO 15189 – Medical laboratories – Requirements for quality and competence ISO/TS20658:2017 – Medical laboratories – Requirements for collection, transport, receipt and handling of samples VIM3 – Vocabulaire International de Métrologie WHO – Guidance on regulations for the Transport of Infectious Substances
Weitere Ziele validation of testing methods
Teilnehmerzahl
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)
Die Durchführung des Ringversuchs ist in Auftrag gegeben durch
Kosten
Teilnahmegebühr on demand
Regelmässig durchgeführt Ja (two times a year)
Der Ringversuch wird durchgeführt seit
Kontaktdaten des Anbieters
Anbieter Kontaktperson
QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Feketesas u. 19-21. I/7
6720 Szeged
Hungary

Telefon: +36 30 462 5864
Fax:
Web: http://www.qualicont.com/qc/index_en.html http://www.qualicont.com/qc/index_en.html
Ms. Eszter Mezey
Telefon: +36 30 462 5864
Fax:
E-Mail: mail@qualicont.com mail@qualicont.com
Haben Sie einen Fehler entdeckt? Bitte wenden Sie sich an den zuständigen EPTIS Koordinator für Hungary, Ms Eszter Mezey. Ms Eszter Mezey.
Haben Sie Fragen? Senden Sie uns eine E-Mail: eptis@bam.de.
Anwendungsversion: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5