Diagnostics of cervical cytology
[Méhnyakcitológia diagnosztikája]
EPTIS Ringversuch Nr. 1278491 | Letze Änderung 2024-10-11 | URL: https://www.eptis.bam.de/pts1278491 https://www.eptis.bam.de/pts1278491
Name des Anbieters | |||||||
Name des Anbieters | QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd. QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd. | ||||||
Ansässig in | Hungary | ||||||
Sprache(n) | English, Hungarian | ||||||
Anmerkungen | Unstained paraffin slides are sent to the participants. Task: Routine staining and detection of immunohistochemical marker molecules on the formaldehyde-fixed paraffin embedded sections distributed by QualiCont (2-2 unstained slides per test/per survey) and on slides of the similar tissue/tumour created in their own laboratory (in-house). Reporting of results: The technical details of the stained sections and the methods are to be sent electronically via Internet. The evaluations and the Certificates are available electronically, too. All smears are available for participants only in digital form. a., Conventional smear 5 healthy and abnormal conventional smears per survey from routine cytology cases, stained according to Papanicolaou. Evaluation according to the Bethesda 2014 classification system via QualiCont's online ’Pathology Program’. After the evaluation, it is possible to review the annotated smears from the reference laboratory on the QualiCont site. A Certificate of participation is issued by QualiCont. b., LBC (liquid based sample) ThinPrep smear 5 healthy and abnormal conventional LBC smears per survey from routine cytology cases, stained according to Papanicolaou. Evaluation according to the Bethesda 2014 classification system via QualiCont's online ’Pathology Program’. After the evaluation, it is possible to review the annotated smears from the reference laboratory on the QualiCont site. A Certificate of participation is issued by QualiCont. c., Conventional and LBC smear It is possible to evaluate both conventional and liquid-based (LBC) smears according to the practice of the laboratory. | ||||||
Klassifizierung | |||||||
Produktgruppen |
Human test material
Health care / medical devices |
||||||
Prüfgebiete |
Medical analysis
|
||||||
Technische Einzelheiten | |||||||
|
|||||||
Ringversuchsziele | |||||||
Zielgruppe des Ringversuchs | In vitro medical laboratories | ||||||
Relevante Rechtsvorschriften oder Normen | ISO 15189 – Medical laboratories – Requirements for quality and competence ISO/TS20658:2017 – Medical laboratories – Requirements for collection, transport, receipt and handling of samples VIM3 – Vocabulaire International de Métrologie WHO – Guidance on regulations for the Transport of Infectious Substances | ||||||
Weitere Ziele | validation of testing methods | ||||||
Teilnehmerzahl | |||||||
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt) | |||||||
Die Durchführung des Ringversuchs ist in Auftrag gegeben durch | |||||||
Kosten | |||||||
Teilnahmegebühr | on demand | ||||||
Regelmässig durchgeführt | Ja (four times a year) | ||||||
Der Ringversuch wird durchgeführt seit | |||||||
Kontaktdaten des Anbieters | |||||||
Anbieter | Kontaktperson | ||||||
QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Feketesas u. 19-21. I/7 6720 Szeged Hungary Telefon: +36 30 462 5864 Fax: Web: http://www.qualicont.com/qc/index_en.html http://www.qualicont.com/qc/index_en.html |
Ms. Eszter Mezey
Telefon: +36 30 462 5864 Fax: E-Mail: mail@qualicont.com mail@qualicont.com |