EPTIS Ringversuch Nr. 1177164 | Letze Änderung 2025-03-17 | URL: https://www.eptis.bam.de/pts1177164 https://www.eptis.bam.de/pts1177164

Name des Anbieters
Name des Anbieters Weqas Weqas
Ansässig in United Kingdom
Sprache(n)
Anmerkungen Preterm labour is defined as regular contractions of the uterus resulting in changes in the cervix that start before 37 weeks of pregnancy. Biomarker tests PartoSure, Actim Partus and quantitative Rapid fetal fibronectin (fFN) are intended for use with other clinical information to assess the risk of preterm birth in women with symptoms of preterm labour who have intact amniotic membranes. Phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) is a biochemical marker used as an aid in assessing the risk of preterm delivery in pregnant women with signs and symptoms of preterm labour and intact amniotic membranes, after 22 weeks plus 0 days of pregnancy. Weqas offers 3 separate programmes, one for qualitative and quantitative fFn and separate programmes for phIGFBP-1 and PAMG-1. Purified human fFN and semi - purified IGFBP-1 are added to an artificial amniotic fluid buffer base containing anti-proteases, detergents, proteins and preservatives to produce high positive samples. The two high positive samples are further diluted with the negative base to create a series of samples spanning the analytical range. Each of the samples are distributed on 2-3 occasions to allow for the assessment of between batch variability. For PAMG-1, material is sourced from a third supplier and currently not produced in house. Key Features: - Liquid stable samples supplied ready to use for fFN and phIGFBP-1; no pre-analytical preparation is required. - Qualitative and Quantitative reporting available.. - Linear related panel distributed covering the clinically relevant range. - Programme assesses both site and device performance, including bias, within and between batch imprecision and linearity for quantitative analytes. - Diagnostic accuracy assessed for the qualitative analytes. - Scoring based on Milan Model 3 performance specification. For more information: https://www.weqas.com/services/poct-eqa/pre-term-labour-markers/ or contact@weqas.com
Klassifizierung
Produktgruppen Health care / medical devices
Prüfgebiete Medical analysis
Technische Einzelheiten
Prüfobjekt Prüfeigenschaft Prüfmethode
Synthetic Amniotic Fluid containing purified fFN, phIGFBP-1 or PAMG-1 Quantitative fFN Routine testing methods (recommended)
Qualitative fFN Routine testing methods (recommended)
phIGFBP-1 Routine testing methods (recommended)
PAMG-1 Routine testing methods (recommended)
Ringversuchsziele
Zielgruppe des Ringversuchs Programme assesses both site and device performance, including bias, within and between batch imprecision and linearity for quantitative analytes.
Relevante Rechtsvorschriften oder Normen Accreditation by UKAS based on ISO/IEC 17043. *PAMG-1 Pilot programme for 2025. Currently not accredited.
Weitere Ziele validation of testing methods
Teilnehmerzahl
Anbieter unabhängig überprüft (akkreditiert, benannt, anerkannt)

Akkreditiert durch UKAS auf der Grundlage von ISO/IEC 17043 *PAM-1 Pilot programme for 2025. Currently not accredited. nicht für alle Parameter

Die Durchführung des Ringversuchs ist in Auftrag gegeben durch
Kosten
Teilnahmegebühr https://www.weqas.com/participantzone/subscription-charges/
Regelmässig durchgeführt Ja (Frequency: Bimonthly. Samples: 2 x 1.0ml for phIGFBP-1, 2 x 0.5mL for fFN and PAMG-1. )
Der Ringversuch wird durchgeführt seit 2013
Kontaktdaten des Anbieters
Anbieter Kontaktperson
Weqas
Unit 6, Parc Ty Glas
CF14 5DU Cardiff
United Kingdom

Telefon: 44 (0) 2920 314750
Fax:
Web: http://www.weqas.com http://www.weqas.com
Laura Lloyd-Lewis
Telefon: 44 (0) 29218 32884
Fax:
E-Mail: laura.lloyd-lewis@wales.nhs.uk laura.lloyd-lewis@wales.nhs.uk