Testing of Procedures Transformer Safety

[Pruebas de Procedimientos de seguridad de transformadores]

EPTIS factsheet 921398 | Last revision 2022-02-09 | URL: https://www.eptis.bam.de/pts921398 https://www.eptis.bam.de/pts921398

PT provider
PT provider Metrologos Especializados e Ingenieros Electricos MEIE S. de R.L. de C.V Metrologos Especializados e Ingenieros Electricos MEIE S. de R.L. de C.V
Based in Mexico
Language(s) English/Español
Remarks
Keywords
Product groups Electrical / electronical devices
Testing fields Electrotechnics / electronics
Technical details
Test item Tested property Testing method
Distribution transformer Voltage, Current, Power, Temperature and Pressure Testing of Procedures Transformer Safety
-
Aims of the PT scheme
Target group of participants ELECTRONIC ELECTRICAL SECTOR TEST LABORATORIES
Linked to specific legislation / standards Measurement of the ohmic (electrical) resistance: Sections 3.1.2 and 3.2 of the standard: NTC 375: 2017; Section 5 of the standard: IEEE Std C57.12.90-2015; section 11.2 of the standard: IEC 60076-1-2011; Sections 4.3.2, 4.3.3 of the standard: MNX-J-169-ANCE-2015; NMX-J-351-2-ANCE-2016;Relation of Transformation: sections: 4.1- 4.2.1 - 4.3.2 - 5.1.2 - 5.2.1 and 5.3.2 of the standard: NTC 471: 2017; section 7 of the standard: IEEE Std. C57.12.90-2015; section 11.3 of the standard: IEC 60076-1-2011; section 6.2.2 of the standard: NMX-J-169-ANCE-2015; NMX-J-351-2-ANCE-2016;Vacuum losses and excitation current: Clause 5 of the standard: NTC 1031: 2019; clause 8 of the standard: IEEE Std. C57.12.90-2015; Clause 11.5 of the standard: IEC 60076-1-2011; clause 7, 7.1, 7.2, 7.2.1.2 of the standard: NMX-J-169-ANCE-2015; NMX-J-351-2-ANCE-2016;Measurement of impedance and short circuit losses due to load: standard: NTC 1031: 2019; clause 9 of the standard: IEEE Std C57.12.90-2012; Clause 11.4 of the standard: IEC 60076-1-2011; clause 4 of the standard: NTC-1005; clauses 8, 8.1, 8.3, 8.4 of the standard: NMX-J-169-ANCE-2015; NMX-J-351-2-ANCE-2016;Applied and induced voltage: clauses 9.5 and 9.6 of the standard: NMX-J-169-ANCE-2015; NMX-J-351-2-ANCE-2016: Clause 6.2 of the standard: NTC 837: 2019; Table 2 of the standard: NTC 836: 2019; Clause 17 of the standard: NTC 3654: 2003; Clause 6.3 of the standard: NTC 837: 2019;Polarity, phasor diagram, phase sequence: clause 5.1.1 of the standard: NMX-J-169-ANCE-2015;Airtightness, clause 11 of the standard: NMX-J-169-ANCE-2015;Measurement of temperature rise (heat measurement, heating test) of the transformer windings, clauses 10, 10.2, 10.3, 10.3.1, 10.3.5 of the standard: NMX-J-169-ANCE-2015; clauses 10.4.2, 10.4.3, 10.4.4 of the standard: NMX-J-169-ANCE-2004, clauses 4.1, 4.2, 4.3, 4.4, 4.5.2, 4.6 and 4.7 of the standard: NTC 316: 1998; Clause 21.1.3 of the standard: NTC 3654: 2003
Additional, subsidiary aims validation of testing methods
Number of participants 2 to 7
Accredited or otherwise reviewed by a 3rd party

Accredited by American Association for Laboratory Accreditation (A2LA)  on the basis of ISO/IEC 17043:2010

A2LA

Operation is commissioned / requested by
Fees and frequency
Participation fee Please, contact us
Regularly operated Yes (January)
Year of first operation 2018
Contact details of the PT provider
Provider Contact person
Metrologos Especializados e Ingenieros Electricos MEIE S. de R.L. de C.V
Sur 105A #702
09060
Mexico

Phone: +5276914255
Fax:
Web: http://metrologosmeie.com/ http://metrologosmeie.com/
Ing Emmanuelle David Mora Muñiz
Phone: +5276914255
Fax:
Email: edavidmm@metrologosmeie.com edavidmm@metrologosmeie.com
If you find any mistakes please contact the responsible EPTIS coordinator in Mexico, Ms Deyanira Martínez. Ms Deyanira Martínez.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.21