Somatic cell count in raw milk
[Recuento de células somáticas en leche cruda]
EPTIS factsheet 512185 | Last revision 2018-11-05 | URL: https://www.eptis.bam.de/pts512185 https://www.eptis.bam.de/pts512185
PT provider | ||||||||||
PT provider | LACM/División de Metrología LACM/División de Metrología | |||||||||
Based in | Chile | |||||||||
Language(s) | Spanish | |||||||||
Remarks | Objectives: - Evaluate the participating laboratories that perform somatic cell counts in raw milk by the fluoro-opto-electronic instrumental method, especially in the flow cytometry alternative, comparing their results with an assigned value that meets the requirements established by IDF Bulletin 469/2013 - The assigned values will be based on the SCC of a milk with high cell content, and obtained from the weighted average 50/50 of the robust average of the instrumental results of the participants and the average of RMD results obtained by two analysts - The PT will include 3 different items with SCC in the range of 200 cells / μL to 850 cells / μL - The reproducibility established in ISO 13366-2: 2008 (E) / IDF 148-2: 2008 (E) for the instrumental method is set as the standard deviation for proficiency assessment - The PT items will be prepared by concentration of milk cells, preparation of a milk with high SCC and dilution of this milk with another of very low SCC | |||||||||
Keywords | ||||||||||
Product groups |
Agriculture
Food and drink |
|||||||||
Testing fields |
Microbiology
|
|||||||||
Technical details | ||||||||||
|
||||||||||
Aims of the PT scheme | ||||||||||
Target group of participants | Laboratories performing milk and dairy product analysis in Chile | |||||||||
Linked to specific legislation / standards | ||||||||||
Additional, subsidiary aims | ||||||||||
Number of participants | 7 to 9 | |||||||||
Accredited or otherwise reviewed by a 3rd party |
Accredited by Entidad Mexicana de Acreditación (ema) acreditación N°PEA-ENS-14 on the basis of ISO 17043:2010 |
|||||||||
Operation is commissioned / requested by | No | |||||||||
Fees and frequency | ||||||||||
Participation fee | Please contact us for this information | |||||||||
Regularly operated | Yes (Biannual) | |||||||||
Year of first operation | 2004 | |||||||||
Contact details of the PT provider | ||||||||||
Provider | Contact person | |||||||||
LACM/División de Metrología
Universidad Austral de Chile, Campus Isla Teja S/N, Valdivia, Chile 5090000 Chile Phone: 56-63-2221247 Fax: 56-63-2221245 |
Mr Andrés Soto
Phone: 56-63-2293274 Fax: 56-63-2221245 Email: metrologia@uach.cl metrologia@uach.cl |