EPTIS
BAM Logo

ENERSOL Interlaboratory Proficiency Trial of Syringes, Needles, Luers and Small-bore connectors

EPTIS factsheet 150393 | Last revision 2024-03-06 | URL: https://www.eptis.bam.de/pts150393 https://www.eptis.bam.de/pts150393

PT provider
PT provider ENERSOL Pty Ltd ENERSOL Pty Ltd
Based in Australia
Language(s) English, Portuguese, Chinese, French, Spanish
Remarks
Keywords
Product groups Health care / medical devices
Testing fields Materials evaluation
Medical analysis
Safety evaluation
Technical details
Test item Tested property Testing method
Syringes, needles, conical fittings with 6% Luer and small-bore connectors Gauging ISO 594
Leakage by pressure decay ISO 80369 (Annex B)
Falling drop positive-pressure liquid leakage ISO 80369 (Annex C)
Subatmospheric-pressure air leakage ISO 80369 (Annex D)
Stress cracking ISO 80369 (Annex E)
Resistance to separation from Axial load ISO 80369 (Annex F)
Resistance to separation from unscrewing ISO 80369 (Annex G))
Resistance to overriding ISO 80369 (Annex H)
Disconnection by unscrewing ISO 80369 (Annex I)
Syringes Cleanliness ISO 7886
ISO 8537
Graduated scale - numbering of scale ISO 7886
ISO 8537
Graduated scale - overall length of scale to nominal capacity line ISO 7886
ISO 8537
Barrel - finger grips ISO 7886
ISO 8537
Performance - dead space ISO 7886
ISO 8537
Performance - freedom from air leakage past piston ISO 7886
ISO 8537
Performance - freedom of liquid leakage past piston ISO 7886
ISO 8537
Tolerance on graduated capacity ISO 7886
ISO 8537
Aims of the PT scheme
Target group of participants
Linked to specific legislation / standards ISO 7886 ISO 594 ISO 80369 ISO 8537 ISO 7864 ISO 9626
Additional, subsidiary aims
Number of participants 15
Accredited or otherwise reviewed by a 3rd party
Operation is commissioned / requested by
Fees and frequency
Participation fee Please contact us
Regularly operated Yes (every 2 years)
Year of first operation 2013
Contact details of the PT provider
Provider Contact person
ENERSOL Pty Ltd
235 Nelson Street
2038 Annandale NSW
Australia

Phone: +61-2-9552 1707
Fax: +61-2-9552 1709
Web: http://www.enersol.com.au http://www.enersol.com.au
Ms. Grace Iskander
Phone: +61-2-9552 1707
Fax: +61-2-9552 1709
Email: giskander@enersol.com.au giskander@enersol.com.au
If you find any mistakes please contact the responsible EPTIS coordinator in Australia, Ms Luminita Antin. Ms Luminita Antin.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5