EPTIS
BAM Logo

Oxidative Burst / Phagocytosis Test (654)

[Oxidativer Burst / Phagozytosetest (654)]

EPTIS factsheet 1450753 | Last revision 2026-01-30 | URL: https://www.eptis.bam.de/pts1450753 https://www.eptis.bam.de/pts1450753

PT provider
PT provider INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories
Based in Germany
Language(s) German, English
Remarks Oxygen radical production in granulocytes after stimulation with PMA and with E. coli (also individually) Stimulation index (DHR) and evaluation (DHR/ NBT) as well as phagocytosis of opsonised E. coli in granulocytes Stimulation index and evaluation. Overnight delivery. The samples should ideally be stimulated and measured within 24-36 h after blood collection. The stimulants are not sent with the samples! This EQA scheme is intended for laboratories that determine oxygen radical production in granulocytes to clarify a granulocyte dysfunction. Shipping within the DACH region only The interdisciplinary, non-profit, scientific and medical association INSTAND e. V. is a reference institution for the quality control of medical laboratories. It is one of four German reference institutions responsible for the organization of external quality assessment (EQA) schemes for quality control in medical laboratories. You can register for EQAs, submit your results and later download your evaluation documents via https://rv-online.instandev.de. The price on our website apply exclusively to orders placed via INSTAND e.V. Prices and services may differ for orders placed via distributors. Our newest EQA program can also be found on our website: https://www.instand-ev.de/en/instand-eqas/eqa-program/
Keywords
Product groups Human test material
Testing fields Medical analysis
Technical details
Test item Tested property Testing method
4 samples of 2 mL whole blood (Heparin), not stabilized Oxygen radical production after stimulation -
Phagocytosis of opsonised E. coli in granulocytes -
Stimulation index and evaluation -
Aims of the PT scheme
Target group of participants
Linked to specific legislation / standards
Additional, subsidiary aims
Number of participants < 50
Accredited or otherwise reviewed by a 3rd party

Accredited by DAkkS (Germany) on the basis of ISO/IEC 17043

German Bundesärztekammer (General medical Council)

Operation is commissioned / requested by
Fees and frequency
Participation fee
Regularly operated Yes (2 times per year)
Year of first operation Experience with operation of ILCs since 1968
Contact details of the PT provider
Provider Contact person
INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories
P.O.Box 250211, Ubierstrasse 20
40223 Düsseldorf
Germany

Phone: +49-211-159213-0
Fax:
Web: http://www.instandev.de/ http://www.instandev.de/
Dr. rer. nat. Nathalie Weiss
Phone: +49-211-159213430
Fax:
Email: weiss@instand-ev.de weiss@instand-ev.de
If you find any mistakes please contact the responsible EPTIS coordinator in Germany, Mr Johannes van de Kreeke. Mr Johannes van de Kreeke.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5