EPTIS
BAM Logo

Cardiac markers

[Kardiális markerek]

EPTIS factsheet 1276507 | Last revision 2024-11-11 | URL: https://www.eptis.bam.de/pts1276507 https://www.eptis.bam.de/pts1276507

PT provider
PT provider QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd. QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Based in Hungary
Language(s) English, Hungarian
Remarks
Keywords
Product groups Health care / medical devices
Human test material
Testing fields Medical analysis
Technical details
Test item Tested property Testing method
2 samples, lyophilized plasma or 1.5 mL liquid samples each BNP Luminescence enzyme immunoassay (LIA)
Electro chemiluminescence immunoassay (ECLIA)
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Chemiluminescence immunoassay (CLIA)
Chemiluminescencent magnetic microcorpuscle-immunoassay (CLMIA)
Nephelometry
Micro particle-enzyme immunoassay (MEIA)
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
Enzyme immunoassay methods (EIA, ELISA)
CK-MB Whole blood POCT immunoassay/Quick test
Mass concentration
Micro particle-enzyme immunoassay (MEIA)
Enzyme activity after neutralization (M- subunit antibody) 37°C
Enzyme immunoassay: heterogeneous methods (EIA, ELISA)
High-pressure liquid chromatography (HPLC)
Nephelometry
Dry fluorescence immunoassay
Mass determination with specific antibody 37°C
Luminescence enzyme immunoassay (LIA)
Electro chemiluminescence immunoassay (ECLIA)
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
ELFA-technique (Enzyme Linked Fluorescence (Assay)
Chemiluminescence immunoassay (CLIA)
Chemiluminescence magnetic microcorpuscle immunoassay (CLMIA)
CK-MB Mass Atomic Absorption Spectroscopy
Chemiluminescence magnetic microparticle immunoassay (CLMIA)
Chemiluminescence assay (CLIA)
Dry fluorescence immunoassay
Electro chemiluminescence immunoassay (ECLIA)
ELFA-technology (Enzyme Linked Fluroescence Assay)
Enzyme activity after neutralization (M- subunit antibody) 37°C
Enzyme immunoassay: heterogeneous methods (EIA, ELISA)
Enzyme immunoassay: homogeneous methods (EMIT)
Flame photometry
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Fluorescent polarisation immunoassay (FPIA)
High-pressure liquid chromatography (HPLC)
High-pressure liquid chromatography-mass spectrometry (HPLC-MS)
Homogenous fluorescens immunoassay
Immunoradiometric assay (IRMA)
Immunturbidimetry
KIMS
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
Luminescencia enzyme immunoassay (LIA)
Mass concentration
Mass determination with specific antibody 37°C
MEIA
MEIA Technology with ABBOTT AXSYM instrument
MEIA Technology with ABBOTT IMx instrument
Multilayer film (MF-FIA)
Nephelometry
Radioimmunoassay (RIA)
Turbidimetry: endpoint with reagent blank
Turbidimetry: endpoint, without reagent blank
Turbidimetry: laser photometer DT
Turbidimetry: other methods
Turbidimetry: peak rate
Turbidimetry: two-point
Whole blood POCT immunoassay/Quick test
D-Dimer EIA, ELISA
Electro chemiluminescence immunoassay (ECLIA)
ELFA-technology (Enzyme Linked Fluroescence Assay)
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Fluorescence immunoassay (FIA)
Immunturbidimetry
LIA
MEIA
POCT
hsCRP Chemiluminescence magnetic microparticle immunoassay (CLMIA)
Electro chemiluminescence immunoassay (ECLIA)
Enzyme immunoassay: heterogeneous methods (EIA, ELISA)
Fluorescence immunoassay (FIA), delayed action and enhanced fluorescence immunoassay (DELFIA)
Immunturbidimetry
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
Luminescencia enzyme immunoassay (LIA)
MEIA Technology with ABBOTT AXSYM instrument
Nephelometry
Radial immundiffusion (RID, Mancini)
Turbidimetry: endpoint with reagent blank
Turbidimetry: endpoint, without reagent blank
Turbidimetry: other methods
Turbidimetry: peak rate
Turbidimetry: two-point
Myoglobin Electro chemiluminescence immunoassay (ECLIA)
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
ELFA-technique (Enzyme Linked Fluorescence (Assay)
Enzyme immunoassay: homogeneous methods (EMIT)
Fluorescent polarisation immunoassay (FPIA)
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Homogen fluorescens immunoassay
Immunoradiometric assay (IRMA)
Immuntrubidimetry
Chemiluminescence immunoassay (CLIA)
KIMS
Luminescence (LIA), enhanced chemiluminescence immunoassay (ECI)
Micro particle-enzyme immunoassay (MEIA)
High-pressure liquid chromatography (HPLC)
Nephelometry
Enzyme immunoassay methods (EIA, ELISA)
Chemiluminescencent magnetic microcorpuscle-immunoassay (CLMIA)
Radioimmunoassay (RIA)
Multilayer film (MF-FIA)
Turbidimetry: laser photometer DT
Turbidimetry: two-point
Turbidimetry: endpoint with reagent blank
Turbidimetry: peak rate
Turbidimetry: endpoint without reagent blank
Turbidimetry: other methods
NT-proBNP Luminescence enzyme immunoassay (LIA)
Electro chemiluminescence immunoassay (ECLIA)
ELFA-technique (Enzyme Linked Fluorescence (Assay)
Enzyme immunoassay: heterogeneous methods (EIA, ELISA)
Enzyme immunoassay: homogeneous methods (EMIT)
Fluorescent polarisation immunoassay (FPIA)
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Homogen fluorescens immunoassay
Immunoradiometric assay (IRMA)
Immuntrubidimetry
Chemiluminescence immunoassay (CLIA)
Chemiluminescencent magnetic microcorpuscle-immunoassay (CLMIA)
KIMS
Micro particle-enzyme immunoassay (MEIA)
Nephelometry
High-pressure liquid chromatography (HPLC)
Radioimmunoassay (RIA)
Multilayer film (MF-FIA)
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
Turbidimetry: laser photometer DT
Turbidimetry: two-point
Turbidimetry: endpoint with reagent blank
Turbidimetry: peak rate
Turbidimetry: endpoint without reagent blank
Turbidimetry: other methods
Troponin-I Whole blood POCT immunoassay/Quick test
Enzyme immunoassay methods (EIA, ELISA)
Micro particle-enzyme immunoassay (MEIA)
Chemiluminescencent magnetic microcorpuscle-immunoassay (CLMIA)
Luminescencia enzyme immunoassay (LIA)
Luminescence enhanced enzyme immunoassays (LEIA, LIEMA)
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
ELFA-technique (Enzyme Linked Assay)
Chemiluminescence immunoassay (CLIA)
Immulite Turbo
Troponin I hs
Nephelometry
Dry fluorescence immunoassay
Troponin-T ES-apparatus
Cardiac Reader quick test
Electro chemiluminescence immunoassay (ECLIA)
Electro chemiluminescence immunoassay, Troponin T high sensitive test
Fluorescence immunoassay (FIA), delayed-action and enhanced fluorescence immunoassay (DELFIA)
Cardiac Troponin T hs Cobas H232, Roche
Nephelometry
Troponin T hs
Aims of the PT scheme
Target group of participants In vitro medical laboratories & general practitioners (adults & children)
Linked to specific legislation / standards CLSI GP44-A4 – Procedures for Handling and Processing of Blood Specimens for Common Laboratory Tests ILAC_G8:09/2019 – Guidelines on Decision Rules and Statements of Conformity ISO 15189 – Medical laboratories – Requirements for quality and competence ISO/TS20658:2017 – Medical laboratories – Requirements for collection, transport, receipt and handling of samples VIM3 – Vocabulaire International de Métrologie WHO – Guidance on regulations for the Transport of Infectious Substances
Additional, subsidiary aims validation of testing methods
Number of participants
Accredited or otherwise reviewed by a 3rd party
Operation is commissioned / requested by
Fees and frequency
Participation fee on demand
Regularly operated Yes (four times a year)
Year of first operation
Contact details of the PT provider
Provider Contact person
QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Feketesas u. 19-21. I/7
6720 Szeged
Hungary

Phone: +36 30 462 5864
Fax:
Web: http://www.qualicont.com/qc/index_en.html http://www.qualicont.com/qc/index_en.html
Ms. Eszter Mezey
Phone: +36 30 462 5864
Fax:
Email: mail@qualicont.com mail@qualicont.com
If you find any mistakes please contact the responsible EPTIS coordinator in Hungary, Ms Eszter Mezey. Ms Eszter Mezey.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5