EPTIS
BAM Logo

Blood cell count

[Mennyiségi vérkép]

EPTIS factsheet 1256329 | Last revision 2024-11-26 | URL: https://www.eptis.bam.de/pts1256329 https://www.eptis.bam.de/pts1256329

PT provider
PT provider QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd. QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Based in Hungary
Language(s) English, Hungarian
Remarks The survey sample is not recommended for Abbott Cell Dyn (3200, 4000, Sapphire, Ruby) devices.
Keywords
Product groups Human test material
Health care / medical devices
Testing fields Medical analysis
Technical details
Test item Tested property Testing method
2 samples of 2 mL preserved, coagulation-inhibited blood Erythrocytes (RBC) Automated count of electrical pulses (impedance method)
Automated count of optical pulses
Haematocrit (centrifugated, PCV) Automated centrifugation method (Hemalog), high speed microhematocrit centrifuge: DIN, < 10 min
Automated centrifugation method (Hemalog), high speed microhematocrit centrifuge: DIN, > 10 min
Automated centrifugation method (Hemalog), not high speed centrifuge
Different length (32 or 90 mm) single-use capillary, high speed microhematocrit centrifuge: DIN, < 10 min
Different length (32 or 90 mm) single-use capillary, high speed microhematocrit centrifuge: DIN, > 10 min
Different length (32 or 90 mm) single-use capillary, not high speed centrifuge
Other mincromethods (Hedin, van Allen) high speed microhematcrit centrifuge: DIN, < 10 min
Other mincromethods (Hedin, van Allen) high speed microhematcrit centrifuge: DIN, > 10 min
Other mincromethods (Hedin, van Allen) not high speed centrifuge
Plasticine-sealed, 75 mm single-use capillary, high speed microhematocrit centrifuge: DIN, < 10 min
Plasticine-sealed, 75 mm single-use capillary, high speed microhematocrit centrifuge: DIN, > 10 min
Plasticine-sealed, 75 mm single-use capillary, not high speed centrifuge
Soldered, 75 mm single-use capillary, high speed microhematocrit centrifuge: DIN, < 10 min
Soldered, 75 mm single-use capillary, high speed microhematocrit centrifuge: DIN, > 10 min
Soldered, 75 mm single-use capillary, not high speed centrifuge: DIN, < 10 min
Wintrobe or other macromethod, high speed macrohematocrit centrifuge: DIN < 10 min
Wintrobe or other macromethod, high speed macrohematocrit centrifuge: DIN > 10 min
Wintrobe or other macromethod, not high speed centrifuge
Haematocrit (electronic) Automated count of electrical pulses (impedance method)
Automated count of optical pulses
Haemoglobin Cyanmethemoglobin, according to DIN 58931 standard
Other (modified) cyanmethemoglobin methods
Oxyhemoglobin
Sodium-dodecyl-sulphate (SDS)-, Sodium lauryl sulphate (SLS) method
Photometric, cyanide-free method
Leukocytes (WBC) count Automated count of electrical pulses (impedance method)
Automated count of optical pulses
Lyses of erythrocyten without washing solution
Lyses of erythrocyten with washing solution
MCV Electrical principle (impedance)
Optical principle
PLT - Platelet count Automated count of electrical pulses, parallel with the RBC count
Automated count of electrical pulses, after flotation
Automated count of optical pulses, parallel with the RBC count
Automated count of optical pulses, after hemolysis
MCH - Mean Corpuscular Haemoglobin Calculated value
MCHC - Mean Corpuscular Haemoglobin Concentration Calculated value
MPV - Mean Platelet Volume Electrical principle (impedance)
Optical principle (light scattering)
RDW-CV Calculated value
RDW-SD Calculated value
Mentzer-index Calculated value
Aims of the PT scheme
Target group of participants In vitro medical laboratories & general practitioners (adults & children)
Linked to specific legislation / standards CLSI GP44-A4 – Procedures for Handling and Processing of Blood Specimens for Common Laboratory Tests ILAC_G8:09/2019 – Guidelines on Decision Rules and Statements of Conformity ISO 15189 – Medical laboratories – Requirements for quality and competence ISO/TS20658:2017 – Medical laboratories – Requirements for collection, transport, receipt and handling of samples VIM3 – Vocabulaire International de Métrologie WHO – Guidance on regulations for the Transport of Infectious Substances
Additional, subsidiary aims validation of testing methods
Number of participants
Accredited or otherwise reviewed by a 3rd party

Accredited by NAH (National Accreditation Authority) on the basis of ISO/IEC 17043:2010

Operation is commissioned / requested by
Fees and frequency
Participation fee on demand
Regularly operated Yes (six times a year)
Year of first operation 1997
Contact details of the PT provider
Provider Contact person
QualiCont In Vitro Diagnostic Quality Control Nonprofit Ltd.
Feketesas u. 19-21. I/7
6720 Szeged
Hungary

Phone: +36 30 462 5864
Fax:
Web: http://www.qualicont.com/qc/index_en.html http://www.qualicont.com/qc/index_en.html
Ms. Eszter Mezey
Phone: +36 30 462 5864
Fax:
Email: mail@qualicont.com mail@qualicont.com
If you find any mistakes please contact the responsible EPTIS coordinator in Hungary, Ms Eszter Mezey. Ms Eszter Mezey.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5