QSE Multi-Inhibitor Proficiency Test

[QSE Multi-Hemmstoffeignungsprüfung]

EPTIS factsheet 1145116 | Last revision 2024-02-06 | URL: https://www.eptis.bam.de/pts1145116 https://www.eptis.bam.de/pts1145116

PT provider
PT provider QSE GmbH QSE GmbH
Based in Germany
Language(s) German/English
Remarks Sample material is frozen raw cow milk (unpreserved). Each samples has a volume of 6 mL. All inhibitors are integrated into the set at MRL level. The aim of the Multi-Inhibitor Proficiency Test for sample set A, B and C is to confirm that your routine inhibitor test analysis detects antibiotic residues in milk at MRL level (maximum residue according to Regulation (EU) No. 37/2010). MRL level corresponds to the requirements of Rohmilchgüteverordnung (RohmilchGütV, Germany). Participation with all sample sets is not obligatory. Sample sets can be ordered separately, so you can individually determine your test scope, vary it annually and thus also optimize your costs. Additional sample material can be provided. Please contact multipt@qse-gmbh.com for registration sheet or if you have any further question. Your QSE GmbH
Keywords
Product groups Food and drink
Testing fields Microbiology
Analytical chemistry
Technical details
Test item Tested property Testing method
Test Set B: Samples (4x milk containing inhibitors at MRL level, 1x inhibitor-free sample) Neomycin (1500 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Tylosin (50 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Sulfamethoxypyridazine (100 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Oxytetracycline (100 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Inhibitor-free sample (1 sample vial) Microbiological tests, rapid tests, other test methods
Test Set A: 10 Samples (8x milk containing inhibitors at MRL level, 2x inhibitor-free samples) Penicillin G (4 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Oxacillin (30 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Cloxacillin (30 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Amoxicillin (4 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Ampicillin (4 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Cefalonium (20 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Cephapirin (60 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Cefoperazone (50 µg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Inhibitor-free samples (2 sample vials) Microbiological tests, rapid tests, other test methods
Test Set C: Samples (3x milk containing inhibitors at MRL level, 2x inhibitor-free samples) Enrofloxacin (100 μg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Ciprofloxacin (100 μg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Marbofloxacin (75 μg/kg; 1 sample vial) Microbiological tests, rapid tests, other test methods
Inhibitor-free samples (2 sample vials) Microbiological tests, rapid tests, other test methods
Aims of the PT scheme
Target group of participants Dairies, Routine Laboratories, Reference Laboratories
Linked to specific legislation / standards
Additional, subsidiary aims
Number of participants 70 Laboratories
Accredited or otherwise reviewed by a 3rd party

Accredited by DAkkS Deutsche Akkreditierungsstelle on the basis of DIN EN ISO/IEC 17043

Operation is commissioned / requested by
Fees and frequency
Participation fee Sample set A: 286,00 €, Sample set B: 286,00 €, Sample set C: 214,00 €
Regularly operated Yes (once a year)
Year of first operation 2021
Contact details of the PT provider
Provider Contact person
QSE GmbH
Hochstatt 2
85283 Wolnzach
Germany

Phone: +49(0)9826 62344
Fax: +49(0)9826 62345
Lisa Kranz
Phone: +49(0)9826 62344
Fax: +49(0)9826 62345
Email: lkranz@qse-gmbh.com lkranz@qse-gmbh.com
If you find any mistakes please contact the responsible EPTIS coordinator in Germany, Mr Johannes van de Kreeke. Mr Johannes van de Kreeke.
Any questions or problems? Please contact us at eptis@bam.de.
Application version: 1.23-SNAPSHOT.20230502124635-7925ae379a631fc1ececff45d2921c8db38877d5